Carbon Fiber (CFRP) Engineering in Florida: Approvals, Calculations and Permitting

Carbon fiber engineering in Florida is rarely held up by the material. It is held up at the permit counter. This page sets out what a building department actually needs before it will approve a CFRP repair, what the calculations have to show, and what changes inside the High Velocity Hurricane Zone.

Sealed drawings and calculationsListed and tested systemsHVHZ submittalsFlorida CA# 30969Inspection during installation

The Short Answer

Carbon fiber works. Getting it permitted is where most jobs stall. A building department is not asking whether carbon fiber is a real repair method, it is asking for five things: signed and sealed engineering drawings, the design calculations behind them, evidence that the system is a listed and tested system rather than loose fabric and whatever epoxy was on the shelf, the manufacturer technical data and installation instructions, and inspection while the work goes in.

Inside the High Velocity Hurricane Zone, which the Florida Building Code defines as Broward and Miami-Dade counties, the evidence bar is higher and the approval route has to be settled before anything is priced. Foundation Masters, LLC, Civil Forensic Engineering, Florida Certificate of Authorization CA# 30969, carries that whole package. This page is about the engineering and the approval. The repair itself is covered on the carbon fiber structural repair page.

Carbon fiber engineering on a Florida bridge, CFRP fabric bonded around a concrete girder soffit with the structural drawings being reviewed on site
Externally bonded carbon fiber on a concrete bridge girder. The laminate goes on in a day. The package that gets it approved is what takes the time.

Why carbon fiber engineering jobs stall at the permit counter

The pattern is consistent. Someone has a cracked beam, a bowing block wall, a slab that will not take the new load, or a garage column coming up in a recertification. Where that column is spalling, the concrete work that has to happen first is concrete restoration. Carbon fiber is proposed because it solves the problem without demolition. Then the permit application goes in with a product brochure attached, and it stops.

It stops because a brochure is not engineering and a data sheet is not an approval. The reviewer has no basis to accept the repair: no demand, no capacity, no failure mode, no evidence the system has been tested as a system, and no plan for who verifies that it was installed the way it was designed. None of that is unreasonable. It is the same thing the code asks for on any other structural element.

What makes carbon fiber different is that the people selling it are frequently material suppliers rather than engineers, so the package that reaches the building department is a material package rather than an engineering package.

What the building department requires

Expect every one of these, and expect them together rather than in installments.

What is requiredWhat it has to show
Signed and sealed engineering drawingsWhere the carbon fiber goes, how many plies, in what orientation, over what length, with what anchorage and what surface preparation. Sealed by a Florida licensed professional engineer.
Design calculationsThe existing member capacity, the demand it has to carry, the shortfall the carbon fiber is making up, and the strengthened capacity with the governing failure mode identified.
A listed, tested systemEvidence that the fabric and the resin were evaluated together. An ICC-ES Evaluation Service Report, a Florida Product Approval, or a Miami-Dade Notice of Acceptance, depending on what the jurisdiction accepts.
Manufacturer technical data and installation instructionsThe published data sheets and the installation manual for the exact system specified, submitted with the package. Evaluation reports commonly require a copy of the design manual and installation manual to be submitted to the code official for each project.
Inspection during installationSurface preparation, mixing, saturation, ply placement, lap lengths, cure and adhesion verified while the work happens. Not signed off afterwards from photographs.

The inspection line is the one most people underestimate. Carbon fiber is a wet lay-up: the quality of the finished laminate is created on site, in the hour it goes on, and it cannot be inspected back into existence later.

Carbon fiber engineering inside the High Velocity Hurricane Zone

This is where most of the confusion lives, and it is worth being precise about it.

High-Velocity Hurricane Zone. This zone consists of Broward and Miami-Dade counties.

2023 Florida Building Code, Chapter 2, Definitions

Miami-Dade County puts it plainly in its own material: the county, with its inclusion in the High Velocity Hurricane Zone, has the most stringent code requirements of the Florida Building Code. The county conveys product approval through a Notice of Acceptance issued by its Product Control Section, and describes the NOA as the medium used to convey approval of a product or system to the building industry.

Running alongside that is the statewide system. Florida Statutes 553.842 establishes product evaluation and approval for statewide use, relying on certification by an approved product evaluation entity, testing laboratory or certification agency against the standards the code specifies. Miami-Dade states that an NOA can be used to obtain the optional State of Florida Product Approval for certain product categories, so the county and state routes are connected rather than competing.

Here is the part that catches people out. An ICC-ES Evaluation Service Report is often presented as though it settles the question. Read a current evaluation report for an externally bonded FRP masonry strengthening system and what it actually states is compliance with the 2021 and 2018 International Building Code and International Residential Code. The Florida Building Code is not named in it. Neither is the High Velocity Hurricane Zone, Miami-Dade, Broward, or a Notice of Acceptance.

That does not make the evaluation report worthless, far from it. It is real third party evidence that the system was tested as a system to a published criterion. It simply does not do the job people assume it does in Florida. Whether a given carbon fiber system is accepted under an NOA, under statewide product approval, or as a site specific engineered alternate is a determination for the building official in that jurisdiction, and the time to establish that is before the job is priced, not after the permit is rejected.

Why raw fabric and generic epoxy usually will not permit

Carbon fabric can be bought by the roll and epoxy by the pail. On paper the numbers look excellent. In a submittal they usually go nowhere, for reasons that are structural rather than bureaucratic.

A carbon fiber repair is not a fabric. It is a system: a specific fabric, with a specific primer, putty and saturant, cured under stated conditions, installed by a stated method. The published strength belongs to that combination. Pair the same fabric with a different resin and the cured thickness changes, the bond behavior changes, and the failure mode can change from fiber rupture to debonding, which fails at a far lower load and with far less warning.

Acceptance criteria exist precisely because of this. ICC-ES evaluates these systems under AC125, the Acceptance Criteria for Concrete and Reinforced and Unreinforced Masonry Strengthening Using Externally Bonded Fiber-Reinforced Polymer (FRP) Composite Systems, and the companion inspection criteria AC178. Loose materials have no evaluation, no reported design values, and nothing a reviewer can check the calculations against.

In the HVHZ that gap is decisive. Outside it, a reviewer may accept a site specific engineered alternate with test data behind it. Either way the engineering has to stand on reported design values, not on a marketing figure.

How the carbon fiber engineering is actually done

The calculation package is not long, but every line of it has to be defensible.

StepWhat happensGoverning reference
Establish the loadsWind, gravity, and any load the building was not originally designed for. On a block wall in Florida the controlling case is normally out-of-plane wind pressure on the face.ASCE/SEI 7-22, referenced by the 2023 Florida Building Code
Establish what is there nowWall or member geometry, materials, reinforcement if any, condition, and the capacity the existing element can be relied on for.TMS 402-16 and TMS 602-16 for masonry, referenced by the 2023 code
Find the shortfallDemand minus existing capacity. If there is no shortfall there is no repair to design, which is an answer worth reaching early.Project specific
Design the CFRPPlies, orientation, width, length, anchorage and development, using design values rather than typical values, with an environmental reduction factor applied for the exposure.ACI PRC-440.2-23 for concrete, ACI PRC-440.7-22 for masonry
Check the failure modeConfirm what governs. Fiber rupture, concrete or masonry crushing, or debonding. Debonding frequently governs, and it drives the surface preparation and anchorage detailing.ACI PRC-440.2-23 and ACI PRC-440.7-22
Document itSealed drawings, calculations, system documentation and an inspection plan, issued as one package.Florida Building Code submittal requirements

Two notes on the numbers. First, design values are not typical values. Typical values are average test results and are not what the calculations run on. Second, the environmental reduction factor is not a formality: exterior and aggressive exposure take a larger reduction than interior, and in a coastal Florida environment that distinction is real.

On the ACI documents, note that the designations changed. The concrete guide is now ACI PRC-440.2-23, which supersedes ACI 440.2R-17. The masonry guide is ACI PRC-440.7-22, which supersedes ACI 440.7R-10. A great many specifications and submittals still cite the old numbers.

Carbon fiber versus the traditional repair

The usual alternative on a block wall is to open the cells, place reinforcement and grout them solid. On a concrete member it is to demolish and rebuild, or to add section. Both work. Both are disruptive.

Externally bonded carbon fiberGrouted cells with reinforcement, or rebuild
DemolitionNone. The wall or member stays in place.Cutting, breaking out, and patching back
Building occupancyUsually stays in use, with the work zone isolatedFrequently requires the area to be vacated
Added dead loadNegligibleGrout, concrete and reinforcement add weight that the foundation already has to carry
Added thicknessA few hundredths of an inch per plySection growth, which can affect clearances and finishes
Time on siteDays on most elementsWeeks, with curing and reinstatement
What decides itLoads, existing condition and what the calculations supportLoads, existing condition and what the calculations support

That last row is the honest one. Carbon fiber is not automatically the right answer. It is the right answer when the demand is a tension shortfall that an externally bonded laminate can make up, the substrate is sound enough to bond to, and the governing failure mode can be controlled. When it is not, the engineering should say so.

How Foundation Masters handles carbon fiber engineering end to end

StageWhat we do
Field evaluationMeasure and assess what is actually there. Geometry, materials, condition, existing reinforcement, exposure, and the reason the element is short.
Engineering and calculationsLoads, existing capacity, shortfall, CFRP design, failure mode. Design values and the appropriate environmental reduction, not catalogue numbers.
Sealed drawingsIssued under Florida Certificate of Authorization CA# 30969 and sealed by a Florida licensed professional engineer.
Product and submittal packageThe system documentation assembled to match the drawings: evaluation report or product approval, technical data sheets, installation instructions.
CoordinationWith the manufacturer on system specifics, and with the building department on the approval route, before the job is priced rather than after it is rejected.
Inspection during installationSurface preparation, mixing, saturation, ply placement, lap and anchorage, cure and adhesion, verified on site while the work goes in and reported.

Foundation Masters, LLC is an engineering company. The point of running the package from one place is that the firm answering the building department is the same firm that produced the calculations and watched the material go on the wall.

Carbon fiber engineering glossary

Plain English for the terms that show up in a CFRP submittal.

TermWhat it means
CFRPCarbon fiber reinforced polymer. Carbon fibers bonded into a cured epoxy matrix so the two act together as one structural material.
FRPFiber reinforced polymer, the family CFRP belongs to. Glass and aramid fibers are also used.
Externally bonded FRPFabric or plate bonded to the outside face of an existing member rather than embedded inside it.
Unidirectional fabricFibers running one way, so the strength is in that one direction. Used where the demand has a clear direction.
Bidirectional fabricFibers running two ways, usually at right angles. Used where demand runs both ways.
Tow, 12KA bundle of filaments. 12K means roughly 12,000 filaments in the bundle.
Areal weight, GSM or oz/yd2How much fiber there is per unit area of fabric. It drives how much capacity one ply provides.
Saturant epoxyThe resin that wets out the fabric and transfers load between the fibers. Fabric and saturant together are the system.
PrimerThe first coat onto the prepared substrate. It penetrates the surface and gives the saturant something to bond to.
Putty or filletThickened epoxy used to fill voids and round off sharp corners so the fabric is not forced around a knife edge.
LaminateThe cured combination of fabric and resin, one ply or several.
Cured thicknessThe thickness of one cured ply. The calculations use this, not the dry fabric thickness.
Tensile strengthThe stress the laminate carries before the fibers rupture.
Tensile modulusStiffness. How much strain results from a given stress. It governs how much load the carbon fiber actually attracts.
Rupture strainThe strain at which the fibers break.
Design value vs typical valueTypical values are average test results. Design values are reduced for statistical scatter. Calculations use design values.
Environmental reduction factorA further reduction applied for exposure. Exterior and aggressive exposure take a larger reduction than interior.
DebondingThe laminate separating from the substrate before the fibers reach their strength. It is frequently the governing failure mode, which is why surface preparation and anchorage carry so much weight.
Out-of-plane vs in-planeOut-of-plane load pushes on the face of a wall, such as wind. In-plane load acts along the length of the wall, such as shear.
ICC-ESICC Evaluation Service. It evaluates products against published acceptance criteria.
ESREvaluation Service Report, the document ICC-ES issues when a system meets the criteria.
AC125Acceptance Criteria for Concrete and Reinforced and Unreinforced Masonry Strengthening Using Externally Bonded Fiber-Reinforced Polymer (FRP) Composite Systems, dated October 2019 and editorially revised December 2020.
AC178Acceptance Criteria for Inspection and Verification of Concrete and Unreinforced Masonry Strengthening Using Fiber-reinforced Polymer (FRP) Composite Systems, dated October 2017 and editorially revised December 2020.
Florida Product Approval, FL numberStatewide approval under Florida Statutes 553.842, listed with an FL number.
Miami-Dade NOANotice of Acceptance. Miami-Dade County calls it the medium used to convey approval of a product or system to the building industry.
HVHZHigh Velocity Hurricane Zone. Chapter 2 of the Florida Building Code defines it as Broward and Miami-Dade counties.
ACI PRC-440.2-23The ACI guide for design and construction of externally bonded FRP systems for strengthening concrete structures. It supersedes ACI 440.2R-17 and was published November 2023.
ACI PRC-440.7-22The ACI guide for externally bonded FRP systems for strengthening masonry structures. It supersedes ACI 440.7R-10 and was published December 2022.
TMS 402 and TMS 602Building Code Requirements for Masonry Structures and Specification for Masonry Structures. The 2023 Florida Building Code references the 2016 editions of both.
ASCE 7Minimum Design Loads and Associated Criteria for Buildings and Other Structures. The 2023 Florida Building Code references ASCE/SEI 7-22.
Florida Building CodeThe 2023 edition is the 8th edition.
Engineer of Record, EORThe engineer carrying responsibility for the structure, or for the portion of it being designed.
Delegated engineeringDesign of a specific component handed to a specialty engineer who seals that portion and submits it into the record set.
Submittal packageEverything handed to the building department together: sealed drawings, calculations, product approval documents, technical data sheets and installation instructions.
Notice of CommencementThe document recorded with the county before construction begins on qualifying work.
40 and 50 year recertificationThe local building recertification programs. Separate from, and now running alongside, the statewide milestone inspection under Florida Statutes 553.899.

Carbon Fiber Engineering Questions

What does a building department need to approve a carbon fiber repair in Florida?

In practice the department is looking for a complete package rather than a single document: signed and sealed engineering drawings, the design calculations behind them, evidence that the system itself is a listed and tested system rather than loose materials, the manufacturer technical data sheets and installation instructions, and a plan for inspection while the work is being installed. Missing any one of those is the usual reason a carbon fiber job sits at the counter.

Does an ICC-ES evaluation report mean a carbon fiber system is approved in Florida?

Not by itself. An ICC-ES Evaluation Service Report states compliance with the International Building Code and the International Residential Code. Reading a current evaluation report for an externally bonded FRP masonry system, the Florida Building Code is not named in it, and neither is the High Velocity Hurricane Zone, Miami-Dade, Broward or a Notice of Acceptance. An evaluation report is strong evidence that a system has been tested to a recognized criterion. Whether that satisfies a particular Florida jurisdiction is a determination for the building official.

What is the High Velocity Hurricane Zone and does it apply to my building?

The Florida Building Code defines it in Chapter 2: the High Velocity Hurricane Zone consists of Broward and Miami-Dade counties. If the building is in either county it is inside the zone. Miami-Dade County describes itself as having the most stringent code requirements of the Florida Building Code because of that inclusion.

Do I need a Miami-Dade Notice of Acceptance for carbon fiber?

Miami-Dade County describes the Notice of Acceptance as the medium used to convey approval of a product or system to the building industry, issued through the Product Control Section. Whether a given carbon fiber system is handled as an NOA product, under statewide Florida Product Approval, or as a site specific engineered alternate is a determination for the building official in that jurisdiction. Settling that question before anything is priced is the single biggest time saver on a Miami-Dade or Broward carbon fiber job.

What is the difference between Florida Product Approval and a Miami-Dade NOA?

Florida Product Approval is the statewide system established under Florida Statutes 553.842, which relies on certification by an approved product evaluation entity, testing laboratory or certification agency against the standards the code specifies. The Miami-Dade Notice of Acceptance is a county approval issued by the Product Control Section. Miami-Dade states that an NOA can be used to obtain the optional State of Florida Product Approval for certain product categories, so the two are related rather than alternatives.

Which standards govern the carbon fiber design calculations?

For concrete, ACI PRC-440.2-23, the guide for design and construction of externally bonded fiber reinforced polymer systems for strengthening concrete structures, which supersedes ACI 440.2R-17. For masonry, ACI PRC-440.7-22, which supersedes ACI 440.7R-10. Loads come from ASCE/SEI 7-22 and the masonry itself is governed by TMS 402-16 and TMS 602-16, which are the editions the 2023 Florida Building Code references.

Can carbon fiber replace filling the cells with grout and rebar?

Often, yes, where the demand is out-of-plane bending on a block wall and the engineering supports it. Externally bonded carbon fiber adds tensile capacity to the face of the wall without opening it up, so there is no demolition, no cutting and patching of cells, and the building can usually stay in use. Whether it is the right answer depends on the loads, the condition of the existing wall and what the calculations show. It is a design decision, not a product preference.

Is carbon fiber accepted for 40 year and 50 year recertification repairs?

Carbon fiber is a repair method, not a category of approval, so the question is always whether the specific repair is engineered and documented to the satisfaction of the building official. Recertification work in Florida now sits alongside the statewide milestone inspection under Florida Statutes 553.899, which requires a milestone inspection of a condominium or cooperative building by a licensed architect or engineer at 30 years of age, and which a local enforcement agency may require at 25 years where local circumstances such as proximity to salt water warrant it.

Sources

Every code edition, standard number and designation on this page was read against a current source rather than quoted from memory: 2023 Florida Building Code, Chapter 2, Definitions for the High Velocity Hurricane Zone; Chapter 35, Referenced Standards for ASCE/SEI 7-22, TMS 402-16 and TMS 602-16; ACI PRC-440.2-23 and ACI PRC-440.7-22 for the FRP design guides and the documents they supersede; Florida Statutes 553.842 for statewide product approval; Florida Statutes 553.899 for milestone inspections; and Miami-Dade County, Ensuring Strict Standards for Construction Materials for the Notice of Acceptance and Product Control.

Code editions change. Confirm the governing edition and any local amendments with the building department and the engineer of record for your project.

Carbon Fiber Engineering for Your Project

Send the drawings if you have them, photographs of the element, and the jurisdiction. We will tell you whether carbon fiber carries the load, what the approval route looks like in that county, and what the submittal package needs to contain.